Pipe Size Chart

Nominal pipe size to actual outside diameter, Schedule 40 and 80 wall thickness and inside diameter.

Calipers across the outside of the pipe
Nominal pipe size
—
NPS

Pipe size chart (NPS, Schedule 40 and 80)

NPSODSch 40 wallSch 40 IDSch 80 wallSch 80 ID
1/8″0.4050.0680.2690.0950.215
1/4″0.5400.0880.3640.1190.302
3/8″0.6750.0910.4930.1260.423
1/2″0.8400.1090.6220.1470.546
3/4″1.0500.1130.8240.1540.742
1″1.3150.1331.0490.1790.957
1-1/4″1.6600.1401.3800.1911.278
1-1/2″1.9000.1451.6100.2001.500
2″2.3750.1542.0670.2181.939
2-1/2″2.8750.2032.4690.2762.323
3″3.5000.2163.0680.3002.900
3-1/2″4.0000.2263.5480.3183.364
4″4.5000.2374.0260.3373.826
5″5.5630.2585.0470.3754.813
6″6.6250.2806.0650.4325.761
8″8.6250.3227.9810.5007.625
10″10.7500.36510.0200.5949.562
12″12.7500.40611.9380.68811.374

All dimensions in inches.

Nominal pipe size is not the OD

A 1/2″ pipe has an outside diameter of 0.840″. Nominal pipe size (NPS) is a historical label: the outside diameter is fixed per size and the wall thickness — the schedule — changes the inside diameter. From 14″ up, NPS equals the OD.

Identifying an unknown pipe

Measure the outside diameter with calipers and enter it. Schedule 40 is standard wall; Schedule 80 is heavier wall with the same OD and a smaller bore, so both fit the same fittings.

Common questions

What is the OD of 1 inch pipe?

1.315″.

What is the difference between Schedule 40 and 80?

Wall thickness. Both have the same outside diameter; Schedule 80 has a thicker wall and smaller inside diameter.

MathApps is free and ad-free for now. If it helped, buy us some art supplies — supporters never see ads, even if we add them.